Eaton Non-Fused Switch Disconnectors - IS Series Isolators
The IS series of main load switch disconnectors from Eaton provide reliable isolation in industrial applications. This range of isolator switches is DIN rail mounted and are suitable for use in many switching and control applications where there is a need to manually power down and disconnect electrical equipment for servicing and maintenance by cutting the power supply to isolated parts of the circuit. These disconnect switches can also be used as safety switches.
These disconnector switches have highly wear-resistant contacts and twin purpose terminals with a capacity of up to 50mm². With an IP40 degree of protection, the devices are suited to industrial environments with a rated uninterrupted current of 16 to 125A. • Load circuit breaker with isolating function
• Performs local isolation, manual override & safety switch functions
• IS Series fit a standard front plate of 45 x 45 mm
• Quick fastening DIN Rail mounting with 2 lock-in positions
• Compatible busbars with switchgear series Xpole by use of the mouth terminal in combination with standard fork busbar
• 2, 3 and 4 pole versions What is the difference between a fused switch disconnector and a non-fused switch disconnector? Unlike fused switch disconnectors, a non-fuse isolator switch does not use a fuse to break or put a circuit into isolation, they instead use a rotary switch or knife-blade disconnect to isolate and de-energise a circuit. Commonly used in industrial automation and control settings.
These disconnector switches have highly wear-resistant contacts and twin purpose terminals with a capacity of up to 50mm². With an IP40 degree of protection, the devices are suited to industrial environments with a rated uninterrupted current of 16 to 125A. • Load circuit breaker with isolating function
• Performs local isolation, manual override & safety switch functions
• IS Series fit a standard front plate of 45 x 45 mm
• Quick fastening DIN Rail mounting with 2 lock-in positions
• Compatible busbars with switchgear series Xpole by use of the mouth terminal in combination with standard fork busbar
• 2, 3 and 4 pole versions What is the difference between a fused switch disconnector and a non-fused switch disconnector? Unlike fused switch disconnectors, a non-fuse isolator switch does not use a fuse to break or put a circuit into isolation, they instead use a rotary switch or knife-blade disconnect to isolate and de-energise a circuit. Commonly used in industrial automation and control settings.

2P Pole Isolator Switch - 20A Maximum Current, IP40
Manufacturer:
Eaton
Manufacturer Part No:
276259 IS-20/2
Enrgtech Part No:
ET22733864
Warranty:
Manufacturer
£ 27.79
Checking for live stock
Number of Poles:
2P
Maximum Current:
20A
IP Rating:
IP40
Voltage Rating:
415V
Electrical Phase:
1
Handle Colour:
Black
Normal State Configuration:
2NO
Switch Rating:
2kA
Length:
35mm
Width:
65.5mm
Depth:
80mm
Throw Configuration:
Single