Phoenix Contact Signal Conditioner, Output Loop-Powered 2-Way Isolator Type, 30V Maximum Input Voltage - MINI MCR-2-UI-I-OLP-PT - 2902063
Looking for a device that can convert electronic signals? Take charge with this Phoenix Contact signal conditioner. When supplied with inputs between 0 and 40mA, it manipulates them into outputs with a maximum current of 32mA. This lets you prepare your transmissions so they're easier to process later down the line in your network. For a fast and flexible setup, the unit uses a push-in method and is mountable in any position.
Humidity is no problem for this product, as it's built to withstand 5 to 95% RH. This makes it suitable for damp areas that experience high levels of non-condensing water vapour. Plus, its PBT housing is resistant to chemicals for a longer service life in heavy-duty applications. You can get an easy handle on the unit, without worrying about shocks, as it has an IP20 rating. • Configurable input to allow for greater versatility
• Compact dimensions of 6.2 (W) x 110.5 (H) x 120.5mm (D) make this a space-saving component
• Broad operating temperature range between -40 and +70°C for use in challenging environments
• Overvoltage category II rating for protection from unplanned voltage surges Output loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of unipolar and bipolar analog signals. Input configurable via DIP switch. Push-in connection technology, standard configuration. Output loop-powered 2-way isolator with plug-in connection technology for the electrical isolation, conversion, and filtering of analog signals. The output loop-powered isolator allows operation at an active analog input module. The device is supplied via the current loop of the controller. On the input side, standard analog signals and non-standard analog signals can be connected, ranging from 2 mA or 50 mV up to 40 mA or 30 V. These are converted to 4 mA ... 20 mA signals. You can configure the input signals via DIP switches. The measuring transducer supports NFC communication.
Humidity is no problem for this product, as it's built to withstand 5 to 95% RH. This makes it suitable for damp areas that experience high levels of non-condensing water vapour. Plus, its PBT housing is resistant to chemicals for a longer service life in heavy-duty applications. You can get an easy handle on the unit, without worrying about shocks, as it has an IP20 rating. • Configurable input to allow for greater versatility
• Compact dimensions of 6.2 (W) x 110.5 (H) x 120.5mm (D) make this a space-saving component
• Broad operating temperature range between -40 and +70°C for use in challenging environments
• Overvoltage category II rating for protection from unplanned voltage surges Output loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of unipolar and bipolar analog signals. Input configurable via DIP switch. Push-in connection technology, standard configuration. Output loop-powered 2-way isolator with plug-in connection technology for the electrical isolation, conversion, and filtering of analog signals. The output loop-powered isolator allows operation at an active analog input module. The device is supplied via the current loop of the controller. On the input side, standard analog signals and non-standard analog signals can be connected, ranging from 2 mA or 50 mV up to 40 mA or 30 V. These are converted to 4 mA ... 20 mA signals. You can configure the input signals via DIP switches. The measuring transducer supports NFC communication.

MACX MCR Series Signal Conditioner, Current, Voltage Input, Current Output, 8 → 30V dc Supply,
Manufacturer:
Phoenix Contact
Manufacturer Part No:
2902063
Enrgtech Part No:
ET22805808
Warranty:
Manufacturer
£ 165.05
Checking for live stock
Module Type:
Loop Powered Isolator
Input Signal Type:
Current, Voltage
Output Signal Type:
Current
Input Range:
2 mA → 40 mA, 50 mV → 30V
Output Range:
4 → 20mA
Supply Voltage:
8 → 30V dc
Hazardous Area Certification:
ATEX
Mounting Type:
DIN Rail Mount
Operating Temperature Range:
-40 → +70°C
Series:
MACX MCR
Minimum Operating Temperature:
-40°C
Signal Conditioner Function:
Isolation