Company Profile
Website |
---|
Reviews
Featured Products
All Products
Hygropalm-HP31 This Versatile handheld instrument is widely recognised as one of the best available in terms of precision, reliability and function when it comes to measuring Humidity and Temperature. With a fixed probe, it is able to perform spot measurements and logging of relative humidity, temperature and psychometric parameters, the integrated Hygromer IN-1 sensor guarantees accurate measuring results. Features and benefits Calculations of relative humidity, temperature and Psychometric<BR/>Graphs and up to four valves can be shown graphically<BR/>Function to set up visual and audible alarms<BR/>Time programmable interval logging, with a memory of 64'000 data points<BR/>Long lasting battery (up to 48h when logging every 30s) Applications The Hygroplam 31 is an instrument that is used to measure temperature and Humidity, ensuring correct temperature and humidity is important in many applications, the HP31 is suitable for Mobile inspection and tests in HVAC, Pharmaceutical industry and building management systems. Supplied with/Kit contains: Hygroplam HP31 (With Fixed Probe)Soft case<BR/>Micro-USB Cable (Computer connection and battery charging<BR/>HW4 Lite (No license key needed. 3 Instruments connected max) What other Hygrometers are available in this Rotronic range? HP32, HP23-A, Hygropalm HP-GTS Approvals/Certification https://www.rotronic.com/en-gb/productattachments/index/download?id=1926 Accessories Soft Case
Show Details
<B>Rotronic HW4-E Software.</B> HW4 is used to monitor, record, chart and analyse precise temperature, humidity and moisture measurements from Rotronic HygroClip2 products. These include a wide range of probe types, handhelds, stand-alone and networked data loggers, wireless systems, transmitters with analogue or digital outputs for controlling processes and water activity analysers used to ensure product quality. Data is saved to the PC and displayed graphically as well as in tabular form. Alarms can be set as required. Moisture values are available. <B>Features and Benefits.</B> <ul><li>Viewing of measured values/Monitoring - Display of measured values on the monitor for one or more nstruments. </li></ul> <ul><li>Display of the measured values - Numeric and graphic display. </li></ul> <ul><li>Analysis and calculation tool - Psychrometric calculations statistics.</li></ul> <ul><li>Printing/Reports Print out as table or graph. </li></ul> <ul><li>Alarms - Visual display of active alarms. </li></ul>
Show Details
Rotronic Instruments Extension Cable For Thermohygrometer E2-02A - 2m Extension cable - used for climatic chambers, the probe in placed in the chamber and not the whole transmitter or logger. <B>For use with the Hygroclip 2 probe see stock number <a href="/web/p/products/6680781">6680781</a>.</B> <B>Applications.</B> Ideal for use in the HVAC, food industry, building services, paper & textile and pharmaceutical industries. <B>Features and Benefits. </B> <ul><li>Accuracy: ±0.8 %rh, ±0.1 K, at 23 °C ±5 K. </li><BR/><li>Range of application: -50…100 °C / 0…100 %rh. </li><BR/><li>Digital interface (UART) and scalable analogue outputs, 0…1 V. </li><BR/><li>Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh. </li><BR/><li>Adjusted at 23 °C and 10, 35, 80 %rh. </li></ul>
Show Details
<B>Rotronic ER-12K Calibration Device.</B> <B>Calibration Chambers.</B> A small stainless steel airtight chamber, to fit onto humidity probe sensors. Screw-mount accepts humidity calibration capsule contents and a textile pad approved humidity calibration capsule available separately. <B>Humidity Calibration Chambers & Capsules.</B> Humidity probe sensor chamber and capsule system generate a precise humidity value environment for humify meter probe calibration, combinations available for most humidity of probe, diameters and calibration values, capsules accepted within ISO9000, FDA and similar quality systems.
Show Details
<B>Rotronic ER-15 Thermohygrometer Calibration Device.</B> <B>Calibration Chambers.</B> A small stainless steel airtight chamber, to fit onto humidity probe sensor. Screw-mount accepts humidity calibration capsule contents and a textile pad approved humidity calibration capsules available separately. <B>Humidity Calibration Chambers & Capsules. </B> Humidity probe sensor chamber and capsule system generate a precise humidity value environment for humify meter probe calibration, combinations available for most humidity of probe, diameters and calibration values, capsules accepted within ISO9000, FDA and similar quality systems.
Show Details
<B>Rotronic HC2-HK25 HygroClip Humidity Temperature Probe.</B> The handheld probe is especially suitable for mobile measurements of high temperatures. It measures humidity and temperature and calculates the dew/frost point. <B>Applications: </B> Climatic and temperature chambers, dryers and air ducts. <B>Features and Benefits.</B> <ul><li>Range of application: -100…200 °C / 0…100 %rh. </li><BR/><li>Digital interface (UART) and scalable analog outputs, 0…1 V. </li><BR/><li>Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh. </li><BR/><li>Adjusted at 23 °C and 10, 35, 80 %rh.</li></ul>
Show Details
<B>HygroClip HC2-HP28 Bulk Packaged Materials Probe.</B> Handheld Probe for Measuring Bulk Packaged Materials The insertion probe is suitable for measurement in bulk materials, bricks, concrete, etc. It measures humidity and temperature and calculates the dew/frost point. <B>Applications.</B> 10mm insertion probe: measurements in dusty bulk materials such as flour, sugar, etc. <B>Features and Benefits.</B> <ul><li>Range of application: -40…85° C/0…100%rh. </li><BR/><li>Digital interface (UART) and scalable analogue outputs, 0...1V Standard. output scaling: 0...1V = -40...60° C / 0...100% rh. </li><BR/><li>Adjusted at 23° C and 10,35,80 % rh.</li></ul>
Show Details
<B>Humidity Calibration Capsules.</B> Calibration using traceable humidity standards is a simple process. Rotronic probes can easily be calibrated using a PC running HW4 software, or via the HP23-A handheld mentioned above. In most of our standards, we use unsaturated salt solutions supplied in packs of five sealed ampoules of the same humidity value. The only exception is in our 0.5 %rh standards, in which we use molecular sieve desiccant. Each ampoule is labelled with its %RH value and serial number. Included with the ampoules are five textile pads and a swiss calibration service (scs) calibration certificate for the batch for traceability and accuracy of the %RH standard.
Show Details
<B>Rotronic EA35-SCS Calibration Standards Thermohygrometer Capsule.</B> Calibration using traceable humidity standards is a simple process. Rotronic probes can easily be calibrated using a PC running HW4 software, or via the HP23-A handheld mentioned above. In most of our standards, we use unsaturated salt solutions supplied in packs of five sealed ampoules of the same humidity value. The only exception is in our 0.5 %rh standards, in which we use molecular sieve desiccant. Each ampoule is labelled with its %RH value and serial number. Included with the ampoules are five textile pads and a swiss calibration service (scs) calibration certificate for the batch for traceability and accuracy of the %RH standard.
Show Details
<B>Rotronic EA50-SCS Thermohygrometer Capsules.</B> Calibration using traceable humidity standards is a simple process. Rotronic probes can easily be calibrated using a PC running HW4 software, or via the HP23-A handheld mentioned above. In most of our standards, we use unsaturated salt solutions supplied in packs of five sealed ampoules of the same humidity value. The only exception is in our 0.5 %rh standards, in which we use molecular sieve desiccant. Each ampoule is labelled with its %RH value and serial number. Included with the ampoules are five textile pads and a swiss calibration service (scs) calibration certificate for the batch for traceability and accuracy of the %RH standard.
Show Details
<B>Rotronic Instruments Compact C11 Data Logger.</B> Compact CL11 Display/Logger has simultaneous CO2, temperature and humidity measurement and logging, with a clear, backlit LC display. Measurements can be, recorded and the data downloaded and analysed with the software included. Carbon dioxide (CO2) levels are a key indicator of indoor air quality in schools, colleges, offices, cinemas, underground spaces and other public areas. A high level of CO2 impairs concentration and decision-making ability. It can be crucial in production processes throughout industry and store rooms where CO2 gas cylinders are kept (regrettably there have been fatalities caused by leaking valves). CO2 monitoring is also important in horticulture, poultry production, test rooms and research projects. <B>Features and Benefits.</B> <ul><li>Rotronic Hygromer IN-1 humidity sensor.</li><BR/><li>40,000 data point memory. Data secure on power loss.</li><BR/><li>Maximum, minimum and average values displayed.</li><BR/><li>Audible and visual CO2 alarms (configurable).</li><BR/><li>Real time clock with back-up battery.</li><BR/><li>Includes mains adapter, SW21 software and USB data cable.</li><BR/><li>Optional external temperature probe.</li></ul> <B>Applications.</B> <ul><li>Classrooms.</li><BR/><li>Conference rooms. </li><BR/><li>Waiting rooms.</li><BR/><li>Indoor areas.</li></ul> <B>Certifications.</B> IP30 rated
Show Details
<B>Rotronic C02-DISPLAY Indoor Air Quality Monitoring Display.</B> Rotronic Wall Mount CO2 Display measures and records CO2, relative humidity and temperature. Accuracy. Carbon dioxide (CO2) levels are a key indicator of indoor air quality in schools, colleges, offices, cinemas, underground spaces and other public areas. A high level of CO2 impairs concentration and decision-making ability. It can be crucial in production processes throughout industry and store rooms where CO2 gas cylinders are kept (regrettably there have been fatalities caused by leaking valves). CO2 monitoring is also important in horticulture, poultry production, test rooms and research projects. A high concentration of carbon dioxide can develop quickly in rooms of all types and indoor public spaces where people are present, when there is insufficient fresh air ventilation. A moderately high CO2 concentration in indoor air causes people to experience rapid fatigue with loss of concentration and decision-making ability. The negative effects become noticeable more quickly in small rooms such as classrooms, conference or meeting rooms, open plan offices, indoor public spaces and elsewhere. <B>Features and Benefits. </B> <ul><li>2.5 %rh, 0.3 C, 30 ppm CO2 +5 % measured value.</li><BR/><li>Rotronic Hygromer IN-1 humidity sensor.</li><BR/><li>18,000 data point memory for CO2, humidity and temperature.</li><BR/><li>Large, easy-to-read, bright and clear display.</li><BR/><li> Adjustable, graphical CO2 air quality indicator.</li><BR/><li>Display of date and time.</li><BR/><li>USB interface for data download.</li></ul>
Show Details