XPS MCWIN, Configuration Software 30 certified safety functions are available with this software and they are easily assignable to the safety outputs. The safety functions have multiple combination possibilities and various starting conditions. The safety functions are certified in accordance with EN 954-1/ISO 13849-1 and IEC 61508. All 8 safety outputs are suitable for use in safety related parts of control systems conforming to category 4 of EN 954-1/ISO 13849-1 and each output can disconnect one of its safety circuits. The main safety functions are as follows: Emergency stop monitoring, with or without time delay, 1 or 2-channel wiringTwo-hand control (type III-C conforming to EN 574-1)Guard monitoring with 1 or 2 limit switches, with or without lockingGuard monitoring for injection presses and blowing machinesCoded magnetic switch monitoringSafety mat monitoringLight curtain monitoring, solid-state and relay output typesZero speed detectionDynamic monitoring of hydraulic valves on linear and eccentric pressesMonitoring safety stop at top dead centre on eccentric pressSafety time delaysMuting function for light curtainsEnabling switch monitoring, 2 or 3 contactLogic OR functionFoot switch monitoringChain shaft breakage monitoringHydraulic and eccentric press monitoringPosition selector