LG 5925 - Emergency stop module, LG 5929 - Expansion module Applications Emergency stop and expansion modules for - Machine emergency stop switching - Monitoring sliding grill guards General data Safety category 4 in accordance with EN954-1 Operating status indicator 22.5 mm overall width Emergency stop module LG 5925.48 1 or 2-channel configuration Line termination recognition on the ON button with or without crossover recognition Expansion module LG 5929.60 Use only with a higher-level emergency stop module Redundant and force guided contacts 1-channel configuration Input Emergency stop module Expansion module Nom. voltage: 230 VAC or 24 VAC / DC 230 VAC or 24 VAC / DC Control voltage: 22 VDC at S11 with U N - Control current: 25 mA with U N 75 mA Output Contact assignment: 3 N/O / 1 N/C 5 N/O / 1 N/C Therm. current I th : 5 A max. 5 A max. Switching capability according to AC 15: - N/O: 3 A / 230 VAC - N/O: 3 A / 230 VAC - N/C: 2 A / 230 VAC - N/C: 2 A / 230 VAC Mechanical lifespan: >20 x 10 6 switching cycles >20 x 10 6 switching cycles General data Rated operating current type: Continuous operation Continuous operation Mounting: DIN rail DIN rail Housing material: Thermoplast Thermoplast Protection class: - Housing: IP40 - Housing: IP40 - Terminals: IP20 - Terminals: IP20 Dimensions (H x W x D): 22.5 x 90 x 121 mm 22.5 x 90 x 121 mm Weight: 220 g 205 g Ambient temperature: -15 °C → +55 °C -15 °C → +55 °C Approvals CE Standards EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1, IEC / EN 60204-01, EN 954-1