The Chauvin Arnoux CA 6422 earth tester is ideal for intensive use in the field. This tester can be used for 2P and 3P earth measurements. The connections are clearly identified with text markings and colour coding. All the measurements and functions are directly accessible on the instrument's front panel, even when you are wearing gloves. The CA 6422 is equipped with a backlit LCD screen which is particularly easy to read. A LED indicates when a hazardous voltage is present, while the NOISE symbol flashes to indicate when a noise voltage is present.
2P resistance measurement up to 50 kΩ / 3P earth up to 2 kΩ
Automatic stabilization of the measurement / Battery life > 2,000 x 3P earth measurements
It has a 2P resistance of 0.05 Ω to 50 kΩ
It is compliant with IEC 61557-1 and IEC 61557-4
It also has one shot or permanent Measurement mode
Automatic stabilization of the measurement / Battery life > 2,000 x 3P earth measurements
It has a 2P resistance of 0.05 Ω to 50 kΩ
It is compliant with IEC 61557-1 and IEC 61557-4
It also has one shot or permanent Measurement mode

CA 6422 Earth & Ground Resistance Tester CAT IV 600 V
Manufacturer:
Chauvin Arnoux
Manufacturer Part No:
P01127012
Enrgtech Part No:
ET21600428
Warranty:
Manufacturer
£ 465.81
Checking for live stock
Best Accuracy:
±(2% reading +1digit)
Display Type:
LCD
Safety Category:
CAT IV 600 V
Model Number p:
CA 6422