MX5060 Bench Digital Multimeter
The MX 5060 bench- top digital multimeter can be used for TRMS AC + DC measurements. The 60000 count double transflective backlit LCD screen with bargraph and central zero offers instantaneous display of the signal variations. To ensure good measurement stability on variable speed drives, the MX 5060 bench multimeter is equipped with a 300 Hz PWM filter.
Simple and effective for your laboratories
• Error-free current measurement up to 10 A thanks to the single A terminal
• TRMS AC+DC and up to 60,000 counts displayed with 100 kHz bandwidth
• Measurement stability with the VLowZ calibre which eliminates spurious voltages
• Measurement stability on variable speed drives with the 300 Hz PWM filter
• Recording and monitoring of the signed Min, Max and Peak values
• Compliance with IEC 61010 1000 V CAT III double insulation, optimized safety Key features of the MX5060 Bench Digital Multimeter • DC, AC and AC + DC current measurement
• DC, AC and AC + DC voltage measurement, as well as peak voltages
• Resistance up to 60 MΩ and continuity
• RMS values
• μV resolution
• Diode test
• Capacitance from 6 nF to 60 mF
• DC, AC and AC+DC voltage measurement, as well as peak voltages
• Frequency up to 60 kHz
• 60 mV calibre
• VDC accuracy: 0.05 % R
• Temperature (K thermocouple) from -200 °C to +1200 °C
• USB communication – SCPI commands Typical applications for the MX5060 Bench Digital Multimeter • Electrical engineering and electronics sector What’s included? • EU Mains power cable
• 1.5 m red straight/straight cable
• 1.5 m black straight/straight cable
• Red CAT IV 1 kV test probe, black CAT IV 1 kV test probe
• Operating manual on CD
• Start-up guide on paper and remote programming manual.
• TRMS AC+DC and up to 60,000 counts displayed with 100 kHz bandwidth
• Measurement stability with the VLowZ calibre which eliminates spurious voltages
• Measurement stability on variable speed drives with the 300 Hz PWM filter
• Recording and monitoring of the signed Min, Max and Peak values
• Compliance with IEC 61010 1000 V CAT III double insulation, optimized safety Key features of the MX5060 Bench Digital Multimeter • DC, AC and AC + DC current measurement
• DC, AC and AC + DC voltage measurement, as well as peak voltages
• Resistance up to 60 MΩ and continuity
• RMS values
• μV resolution
• Diode test
• Capacitance from 6 nF to 60 mF
• DC, AC and AC+DC voltage measurement, as well as peak voltages
• Frequency up to 60 kHz
• 60 mV calibre
• VDC accuracy: 0.05 % R
• Temperature (K thermocouple) from -200 °C to +1200 °C
• USB communication – SCPI commands Typical applications for the MX5060 Bench Digital Multimeter • Electrical engineering and electronics sector What’s included? • EU Mains power cable
• 1.5 m red straight/straight cable
• 1.5 m black straight/straight cable
• Red CAT IV 1 kV test probe, black CAT IV 1 kV test probe
• Operating manual on CD
• Start-up guide on paper and remote programming manual.

MX 5060 Bench Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max
Manufacturer:
Metrix
Manufacturer Part No:
MX5060
Enrgtech Part No:
ET13899912
Warranty:
Manufacturer
£ 466.65
Checking for live stock
Multimeter Type:
Bench
Model Number p:
MX 5060
Display Type:
Digital
Functions Measured:
AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature
Absolute Maximum Resistance Measurement:
60MΩ
Absolute Maximum AC Current Measurement:
10A ac
Absolute Maximum DC Current Measurement:
10A dc
Absolute Maximum DC Voltage Measurement:
1000V dc
Absolute Maximum AC Voltage Measurement:
1000V ac
Absolute Maximum Capacitance Measurement:
60mF
Absolute Maximum Temperature Measurement:
+1200°C
Connectivity:
USB
Related products
£ 335.93