Company Profile
Website |
---|
Reviews
Featured Products
All Products
The Metrix HX0094 with banana connector can be used for 4-20 mA current loop measurement by means of a built-in shunt. It is ideal for applications in the automation and process sectors. Reference conditions Temperature: from 18° C to 28° CRelative humidity: from 20 % to 75 %Use conditions Altitude Operating temperature -10° C to +55° CDC measurement coefficient 25 mV / mAImpedance 250 Ω max
Show Details
30 & 50 MHz differential probes for MX 9030-Z, MTX 1032-B and MTX 1032-C oscilloscopes An indispensable accessory for analogue or digital oscilloscopes to visualise signals that are not referenced to the ground!A range of three models to fulfil different requirements.1 or 2 input channels.Coaxial or banana measuring leads/long length banana leads.A model with coaxial inputs that can be used with oscilloscope probes.30 MHz or 50 MHz bandwidth.Mains or battery power (depending on model).Presented in laboratory casing or handheld probe with wrist strap.Input voltage differential range of ±0.1 → ±600 V (depending on model).Meets standards up to 600 V - CAT IV (depending on model).Compatible with all types of class 1 oscilloscope.Mechanical compatibility with oscilloscopes from the MTX family.Conforms to DBT safety standards in accordance with IEC 61010-1 (2001).Conforms to CEM standards in accordance with NF EN 61326-1 (07/97) + A1 (10/98) + A2 (2001).
Show Details
MX5060 Bench Digital Multimeter The MX 5060 bench- top digital multimeter can be used for TRMS AC + DC measurements. The 60000 count double transflective backlit LCD screen with bargraph and central zero offers instantaneous display of the signal variations. To ensure good measurement stability on variable speed drives, the MX 5060 bench multimeter is equipped with a 300 Hz PWM filter. Simple and effective for your laboratories • Error-free current measurement up to 10 A thanks to the single A terminal• TRMS AC+DC and up to 60,000 counts displayed with 100 kHz bandwidth• Measurement stability with the VLowZ calibre which eliminates spurious voltages• Measurement stability on variable speed drives with the 300 Hz PWM filter• Recording and monitoring of the signed Min, Max and Peak values• Compliance with IEC 61010 1000 V CAT III double insulation, optimized safety Key features of the MX5060 Bench Digital Multimeter • DC, AC and AC + DC current measurement• DC, AC and AC + DC voltage measurement, as well as peak voltages• Resistance up to 60 MΩ and continuity• RMS values• μV resolution• Diode test• Capacitance from 6 nF to 60 mF• DC, AC and AC+DC voltage measurement, as well as peak voltages• Frequency up to 60 kHz• 60 mV calibre• VDC accuracy: 0.05 % R• Temperature (K thermocouple) from -200 °C to +1200 °C• USB communication – SCPI commands Typical applications for the MX5060 Bench Digital Multimeter • Electrical engineering and electronics sector What’s included? • EU Mains power cable• 1.5 m red straight/straight cable• 1.5 m black straight/straight cable• Red CAT IV 1 kV test probe, black CAT IV 1 kV test probe• Operating manual on CD• Start-up guide on paper and remote programming manual.
Show Details
MX5006 Bench Multimeter The MX 5006 bench- top digital multimeter can be used for TRMS AC + DC measurements. The 6000 count double transflective backlit LCD screen with bargraph and central zero offers instantaneous display of the signal variations. To ensure good measurement stability on variable speed drives, the MX 5006 bench multimeter is equipped with a 300 Hz PWM filter. DC, AC and AC + DC current measurementDC, AC and AC + DC voltage measurement, as well as peak voltagesResistance up to 60 MΩ and continuityRMS valuesμV resolutionDiode testCapacitance from 6 nF to 60 mFDC, AC and AC+DC voltage measurement, as well as peak voltagesFrequency up to 60 kHz60 mV calibreVDC accuracy: 0.05 % RTemperature (K thermocouple) from -200 °C to +1200 °CUSB communication – SCPI commands
Show Details
The Chauvin Arnoux set of insulated male BNC plug and on opposite side insulated female BNC plug which has 4 mm of diameter with 19 mm of spacing. Red and black colour
Show Details
Pocket clamp multimeters MX 350 and MX 355 Clamp-on ammeters for data acquisition.Ergonomic, with 6000 count display, to measure voltage and AC and DC currents.The hold function holds the measured value in difficult access or low-light conditions for analysis at a later time.Combines different functions:multimeter, voltage and AC current measurement, ohmmeter and continuity testing.The MX355's Δ Zero function allows the Zero dc to be automatically set, and can also be used for differential measurements.Supplied with two batteries, a set of test leads and a carry case.Available in calibrated version.
Show Details
30 & 50 MHz differential probes for MX 9030-Z, MTX 1032-B and MTX 1032-C oscilloscopes An indispensable accessory for analogue or digital oscilloscopes to visualise signals that are not referenced to the ground!A range of three models to fulfil different requirements.1 or 2 input channels.Coaxial or banana measuring leads/long length banana leads.A model with coaxial inputs that can be used with oscilloscope probes.30 MHz or 50 MHz bandwidth.Mains or battery power (depending on model).Presented in laboratory casing or handheld probe with wrist strap.Input voltage differential range of ±0.1 → ±600 V (depending on model).Meets standards up to 600 V - CAT IV (depending on model).Compatible with all types of class 1 oscilloscope.Mechanical compatibility with oscilloscopes from the MTX family.Conforms to DBT safety standards in accordance with IEC 61010-1 (2001).Conforms to CEM standards in accordance with NF EN 61326-1 (07/97) + A1 (10/98) + A2 (2001).
Show Details
The Chauvin Arnoux EURO socket test lead for MX535 and CA 6133 tester. Black colour lead
Show Details
MX531 2P+E electric socket tester, earth & 30 mA RCD tests The MX531 is a 3-in-1 controller that can be connected to any TT electrical socket to check that the electrical installation is operating correctly. This tester measures the voltage and displays the connections of the line, neutral and earth conductors in a 2P+E socket. The MX531 tester automatically measures the RE earth resistance value without tripping any RCDs. This tester also tests the presence and the trip of the 30 mA RCD. Strengths Totally autonomous (no battery)Immediate display without adjustments and with pictogram confirmation allowing an easy interpretation of the measurementsCompact size for easy use in confined spacesRotating head to adapt to all socket configurations State at delivery The MX531 is delivered in a neutral cardboard box with a coloured band, equipped with a carrying bag and a user's manual in 4 languages on paper.
Show Details
MX 670 and MX 675 Clip-On Multimeters TRMS AC or AC / DC clip-on multimeters, 10000-count dual display, 600 V CAT IV.The dual display of these clamps enables voltage and current measurements to be viewed simultaneously.Functions: HOLD, AUTO-HOLD, MIN, MAX, Peak, Ø Zero.For measuring current, voltage, frequency, resistance / continuity and temperature (via the K thermocouple sensor covering a range from -40 °C → +1200 °C).The MX 670, AC TRMS can be used to measure currents up to1000 A AC.The MX 675, AC / DC TRMS can be used to measure continuous currents up to 1400 A DC and 1000 A AC.
Show Details
MX 670 and MX 675 Clip-On Multimeters TRMS AC or AC / DC clip-on multimeters, 10000-count dual display, 600 V CAT IV.The dual display of these clamps enables voltage and current measurements to be viewed simultaneously.Functions: HOLD, AUTO-HOLD, MIN, MAX, Peak, Ø Zero.For measuring current, voltage, frequency, resistance / continuity and temperature (via the K thermocouple sensor covering a range from -40 °C → +1200 °C).The MX 670, AC TRMS can be used to measure currents up to1000 A AC.The MX 675, AC / DC TRMS can be used to measure continuous currents up to 1400 A DC and 1000 A AC.
Show Details