<B>PNOZ Sigma Series 2 by PILZ</B> The PNOZ S2 series of Safety relay by PILZ. Known for their reliability and durability, PILZ safety relays offer you second to none safety protection features to ensure you and your workplace stay safe. Specifically, the S2 series is suitable for many different applications which you can find listed below. <B>Features and Benefits:</B> • LED display that offers you the following measures:<BR/>- Supply voltage<BR/>- Input status, channel 1<BR/>- Input status, channel 2<BR/>- Switch status, safety contacts<BR/>- Reset Circuit<BR/>- Error indication<BR/>• Operating mode can be set via rotary switches<BR/>• The S2 keeps safe separation of safety contacts from all your other circuits<BR/>• Plug in connection terminals<BR/>• 3 safety contacts N/O & 1 auxiliary contact N/C (both instantaneous) <B>Safety features</B> • Self-monitoring built in<BR/>• Safety functions remain effective in the case of components failure<BR/>• Correct opening and closing is tested automatically at the end of each on / off cycle<BR/>• The transform uses an electronic fuse which prevents short circuiting. Applications • E STOP pushbutton<BR/>• Safety gate limit switches<BR/>• Reset buttons <B>Technical safety parameters</B> • EN 60947-5-1<BR/>• EN 60204-1<BR/>• VDE 0113-1 <B>How do Safety Relays work and what are they used for?</B> Safety Relays work by helping reduce unnecessary risk and hazard within your circuit. A typical circuit configuration may look like a production line where highly automated machinery works quickly, i.e. a production or packing line in a warehouse or factory. This line forms part of your 'circuit' and along that circuit you will have safety devices in place like emergency push buttons, safety curtains or pressure sensitive mats. <BR/>To ensure complete safety in these environments, a safety relay can be added to your circuit to allow you full control and monitoring of your working environment. A safety relay will run regular checks down your circuit by sending pulses back and forth to confirm whether any (for example) wiring was implemented incorrectly or any welding has occurred along the circuit. Once the relay has detected this, it would then shut down the area by cutting off the power, until the fault can be determined and fixed. Most recent safety relays feature intuitive LED displays that will alert users to any faults, this is of course useful to prevent harm to users and also proactively engage in maintenance before any machinery is damaged beyond repair, so certain cost savings can be associated when using a safety relay.<BR/>Some safety relays have specific functions and only work with certain devices like E-STOPs, some work better with other devices like safety curtains. More than one safety relay can be used to give you total monitoring of your circuit, ensuring you and your employees safety. <B>What are the differences between a traditional 'relay' and a 'safety relay'?</B> A traditional relay will open and close your circuit and the switch devices down that line, however it will not monitor it in the same way a safety relay will and cannot automatically shut down specified areas to prevent harm to the machinery or workers. Safety relays are not prone to the same potential risks that traditional relays are and can be relied upon to monitor short circuit faults, ground faults or wire breakage. Offering a greater protection over their counterpart relays, they are specifically designed with your safety in mind. <B>How do you operate a Safety Relay?</B> You must first align and wire the safety relay into your line and follow the setup instructions provided (will vary per manufacturer). Follow the onscreen instructions of the LED parallel to your instructions to perform integration into your circuit line. Depending on what parameters you set will determine the function of the safety relay (i.e. you tell it to cut off certain areas after certain criteria have been met, or you opt for a circuit wide halt of the line).
Show Details"Infrared protected field is generated LED indicator for status information Optical synchronisation of transmitters and receivers Aluminium alloy housing Die-cast zinc end caps Shock resistance "
Show DetailsPilz Non-contact Switch The Pilz PSENmag series non-contact safety switch has an assured switching distance of 3mm. It has 1NO/1NC safety contact. It meets the highest safety requirements and offers a complete solution that is safe and economical.<BR/>Supplied with actuator<BR/>Caution: <BR/>EN60947-5-3 standard is only met if the entire system consisting of a safety switch (PSENmag), an actuator (PSENmag) and a safety-monitoring module (PNOZ X) is used.<BR/>Note: <BR/>Only stock nos. 744-8702 and 824-4918 have an LED. Features and Benefits Input The supply voltage is 24VDC<BR/>Connected via a plug connection or with cable <BR/>Flexible cable outlet, including connector, so there is no need for an angled connector <BR/>Flexible mounting, both the sensor and actuator support every conceivable mounting configuration <BR/>Cost effective because of the series connection <BR/>Extra signal contact<BR/>Connection type is M8, 4-pin male <BR/>Housing material is Plastic<BR/>Operating temperature ranges between -25°C and 70°C Applications Heavy soiling Certifications IP65 rated<BR/>IP67 rated<BR/>EN954-1 (Cat 4)<BR/>EN60204-1<BR/>EN60947-5-3<BR/>ATEX approved <BR/>Electrosuisse certified<BR/>CE certified<BR/>UL approved <BR/>TÜV certified <BR/>BG certified <BR/>CCC certified
Show DetailsPilz Non-contact Switch The Pilz PSENmag series non-contact safety switch has an assured switching distance of 3mm. It has 2NO safety contact. It meets the highest safety requirements and offers a complete solution that is safe and economical.<BR/>Supplied with actuator<BR/>Note: <BR/>Only stock nos. 744-8702 and 824-4918 have an LED. Features and Benefits Input The supply voltage is 24VDC<BR/>Connected via a plug connection or with cable <BR/>Flexible cable outlet, including connector, so there is no need for an angled connector <BR/>Flexible mounting, both the sensor and actuator support every conceivable mounting configuration <BR/>Cost effective because of the series connection <BR/>Extra signal contact<BR/>Connection type is M8, 4-pin male <BR/>Housing material is PBT<BR/>Operating temperature ranges between -25°C and 70°C Applications Heavy soiling Certifications IP65 rated<BR/>IP67 rated<BR/>EN954-1 (Cat 4)<BR/>EN60204-1<BR/>EN60947-5-3<BR/>ATEX approved <BR/>Electrosuisse certified<BR/>CE certified<BR/>UL approved <BR/>TÜV certified <BR/>BG certified <BR/>CCC certified
Show DetailsPilz Non-contact Switch The Pilz PSENmag series non-contact safety switch has an assured switching distance of 3mm. It has 1NO/1NC safety contact. It meets the highest safety requirements and offers a complete solution that is safe and economical.<BR/>Supplied with actuator<BR/>Caution: <BR/>EN60947-5-3 standard is only met if the entire system consisting of a safety switch (PSENmag), an actuator (PSENmag) and a safety-monitoring module (PNOZ X) is used.<BR/>Note: <BR/>Only stock nos. 744-8702 and 824-4918 have an LED. Features and Benefits Input The supply voltage is 24VDC<BR/>Status indicator with LED<BR/>Extra signal contact <BR/>Connected via a plug connection or with cable <BR/>Flexible cable outlet, including connector, so there is no need for an angled connector <BR/>Flexible mounting, both the sensor and actuator support every conceivable mounting configuration <BR/>Cost effective because of the series connection <BR/>Connection type is M8, 4-pin male <BR/>Housing material is Plastic<BR/>Operating temperature ranges between -25°C and 70°C Applications Heavy soiling Certifications IP65 rated<BR/>IP67 rated<BR/>EN954-1 (Cat 4)<BR/>EN60204-1<BR/>EN60947-5-3<BR/>ATEX approved <BR/>Electrosuisse certified<BR/>CE certified<BR/>UL approved <BR/>TÜV certified <BR/>BG certified <BR/>CCC certified
Show DetailsPilz Safety Interlock Switch The Pilz PSENsgate safety interlock switch has a supply voltage rating of 24VDC. It has 2NC safety contact. This is a gate monitoring system combines secure safety gate monitoring, safe guard locking and control elements in one system. Also, additional functions such as E-STOP and escape release are included with this non-contact switch. Features and Benefits Actuator type is handle<BR/>Release type is turn release<BR/>Safe guard locking device<BR/>Safe interlocking<BR/>Transponder technology<BR/>2 safety inputs for series connection of several safety switches<BR/>2 safety output<BR/>Locking pin keeps the bolt tongue from being opened unintentionally<BR/>Detection of bolt tongue and locking pin breakage<BR/>Padlock for restart interlock<BR/>Auxiliary release for opening the safety gate, when the plant's voltage is switched OFF<BR/>Escape release for fast release in emergency situations from within the danger zone<BR/>Suitable for left and right hinged gates<BR/>Plug-in spring-loaded terminals<BR/>LED for supply voltage/fault, gate closed, status of the hazardous machinery, status of the inputs, bolt tongue is engaged<BR/>Conduit entry is M12 Certifications IP54 rated <BR/>VDE 0660 T100<BR/>EN 60947-1<BR/>VDE 0660 T200<BR/>EN 60947-5-1<BR/>IEC 60947-5-1<BR/>GS-ET-19<BR/>EC certified<BR/>BG certified<BR/>TUV certified<BR/>CE certified<BR/>CSA certified
Show Details<B>PNOZ X7 series by PILZ, Single Channel</B> The PNOZ X7 range of Safety Relays by PILZ introduces your circuit to a safety related interruption wherein the primary applications are typically in potential hazardous environments where you need that quick power cut off. Particularly useful in automated environments with high foot traffic such as factories, warehouse and the like. <B>Features and benefits</B> • 2 N/O Safety Contacts<BR/>• Feedback control loop is available, this allows you to monitor external relays/contractors<BR/>• LED status indication as standard with the X7 giving you complete assurance as you monitor things like the supply voltage.<BR/>• Redundancy is built in with self-monitoring available.<BR/>• The X7 will automatically test its self at each power up giving you complete reliability and assurance every time your circuit needs to continue its work. <BR/>• DIN rail mounting as standard.<BR/>• Automatic and manual reset facilities available with the X7. <B>Safety features </B> • The circuit is redundant with built in self-monitoring <BR/>• The safety function of the device remains effective even in the event of a component failure along the line<BR/>• Automatic testing on each on-off cycle <B>Applications</B> • Emergency stop buttons <BR/>• Reset buttons<BR/>• External relays/contactors <B>Technical safety parameters</B> • EN 60204-1<BR/>• IEC 60204-01
Show Details<B>PNOZ X5, Dual Channel by PILZ</B> The PNOZ X5 range of Safety Relays by PILZ introduces your circuit to a safety related interruption wherein the primary applications are typically in potential hazardous environments where you need that quick power cut off. Particularly useful in automated environments with high foot traffic such as factories, warehouse and the like.<BR/>PNOZ safety relays prove themselves every day in millions of applications worldwide. PNOZ Safety relays have quickly progressed to be the world’s most commonly used safety relay. These ranges of PNOZ relays are continually being developed to ensure safety is synonymous with the PILZ PNOZ relays. <B>Features and benefits</B> • 2 N/O Safety Contacts<BR/>• DIN Rail mounting as standard<BR/>• LED status indication to show supply voltage in the device<BR/>• Automatic or manual reset facility<BR/>• Simple, fast wiring<BR/>• Separate opening for checking the voltage<BR/>• Great contact security, even when faced with heavy shock and vibration of certain machine types<BR/>• High plant availability and short downtimes thanks to the convenient diagnostic options built into the device<BR/>• Complete solutions comprising of evaluation devices, compatible with sensor technology and control and signal devices.<BR/>• Universal power supply<BR/>• Tailor-made safety for each function<BR/>• Electromechanical, potential-free <B>Safety features </B> • Redundancy is built in with self-monitoring available<BR/>• Self-monitoring relay of the circuit to ensure redundancy when needed<BR/>• Component failure does not compromise the device or circuit it is intended to look after<BR/>• Electronic fuses built in as standard<BR/>• Automatic testing of the on-off cycle<BR/>• International certification, ensuring your safety <B>Applications</B> • Monitoring relays<BR/>• Line inspection devices<BR/>• Small control systems<BR/>• ESTOP pushbuttons <B>Technical safety parameters</B> • EN 60947-5-1<BR/>• EN 60204-1<BR/>• VDE 0113-1
Show Details<B>PNOZ X7 series by PILZ, Single Channel</B> The PNOZ X7 range of Safety Relays by PILZ introduces your circuit to a safety related interruption wherein the primary applications are typically in potential hazardous environments where you need that quick power cut off. Particularly useful in automated environments with high foot traffic such as factories, warehouse and the like. <B>Features and benefits</B> • 2 N/O Safety Contacts<BR/>• Feedback control loop is available, this allows you to monitor external relays/contractors<BR/>• LED status indication as standard with the X7 giving you complete assurance as you monitor things like the supply voltage.<BR/>• Redundancy is built in with self-monitoring available.<BR/>• The X7 will automatically test its self at each power up giving you complete reliability and assurance every time your circuit needs to continue its work. <BR/>• DIN rail mounting as standard.<BR/>• Automatic and manual reset facilities available with the X7. <B>Safety features </B> • The circuit is redundant with built in self-monitoring <BR/>• The safety function of the device remains effective even in the event of a component failure along the line<BR/>• Automatic testing on each on-off cycle <B>Applications</B> • Emergency stop buttons <BR/>• Reset buttons<BR/>• External relays/contactors <B>Technical safety parameters</B> • EN 60204-1<BR/>• IEC 60204-01
Show Details<B>PNOZ X7 series by PILZ, Single Channel</B> The PNOZ X7 range of Safety Relays by PILZ introduces your circuit to a safety related interruption wherein the primary applications are typically in potential hazardous environments where you need that quick power cut off. Particularly useful in automated environments with high foot traffic such as factories, warehouse and the like. <B>Features and benefits</B> • 2 N/O Safety Contacts<BR/>• Feedback control loop is available, this allows you to monitor external relays/contractors<BR/>• LED status indication as standard with the X7 giving you complete assurance as you monitor things like the supply voltage.<BR/>• Redundancy is built in with self-monitoring available.<BR/>• The X7 will automatically test its self at each power up giving you complete reliability and assurance every time your circuit needs to continue its work. <BR/>• DIN rail mounting as standard.<BR/>• Automatic and manual reset facilities available with the X7. <B>Safety features </B> • The circuit is redundant with built in self-monitoring <BR/>• The safety function of the device remains effective even in the event of a component failure along the line<BR/>• Automatic testing on each on-off cycle <B>Applications</B> • Emergency stop buttons <BR/>• Reset buttons<BR/>• External relays/contactors <B>Technical safety parameters</B> • EN 60204-1<BR/>• IEC 60204-01
Show Details<B>PNOZ X3 Series of Safety Relays by PILZ</B> The PNOZ X3 range of Safety Relays by PILZ introduces your circuit to a safety related interruption wherein the primary applications are typically in potential hazardous environments where you need that quick power cut off. Particularly useful in automated environments with high foot traffic such as factories and warehouses. <B>Features and benefits</B> • LED indicator statuses to support switching channel status between 1 or 2 signals & also for monitoring the supply voltage currently in the relay<BR/>• Semiconductor output signals: switch status channel 1 / 2 <BR/>• 3 safety contacts and 1 auxiliary contact<BR/>• Several connection outputs & status indicators<BR/>• Your opening and closing of the safety function relays is tested automatically within each on-off cycle<BR/>• A monitored manual reset is available in this unit<BR/>• DIN rail mounting as standard <B>Safety features </B> • The circuit is redundant with built in self-monitoring <BR/>• Reliable X3 functionality means your safety function remains effective even in the event of component failure<BR/>• The transformer is short circuit proof and an electronic fuse is used on a DC supply. <B>Applications</B> • Emergency stop buttons <BR/>• Safety gate limit switches<BR/>• Reset buttons<BR/>• Light barriers <B>Technical safety parameters</B> • EN 60204-1<BR/>• EN (IEC) 62061<BR/>• EN ISO 13849-1<BR/>• VDE 0113-1<BR/>• EN 60947-5-1